The C dc to MHz manual step attenuator provides precision step attenuation in 1 dB steps from 0 to 12 dB. Attenuator sections are inserted and removed by cam-actuated microswitches which keep lead lengths short. This design minimizes stray capacitances and inductances, and keeps phase shift to a . · HP C and HP D VHF precision attenuation from dc to MHz is available with these attenuators. Model C provides 0 to 12 dB in 1-dB steps and Model D provides 0 to dB in dB steps. Option Type N connector ’s are ideally suited for applications such as receiver testing where minimum leakage is important. Option ’s may be coupled together with an N Availability: In stock. C and D in series provides precision, the attenuation in 1-dB steps from 0 to dB. Also, these attenuators may be connected with either terminal as input or output. Basic design A departure from the usual attenuator design has resulted in an accurate, compact, and rugged attenuator with low insertion loss and low SWR. Error is reduced to a minimum.
hp c/d/e/f attenuators perf orig hp a/a spec an prog manual hp a/b/a netw analyser good orig hp a gain-phase meter perf orig hp a gain-phase meter perf orig hp a gain/phase meter good orig hp a/c wave analyzer poor copy. Hi All, I just recently acquired a set of HP Step Attenuators (C D). I wanted to check them out so I downloaded the manual from Keysight and I'm trying to follow the quick check procedure for the C: The problem that I'm running into is that with the E range set to 10dB and 0dB expand the meter is pegged all the way over to the right - even with the gain vernier turned fully. We can supply the Agilent HP C MHz 75 Ohm S Parameter Test Set. We have thousands of model numbers in stock. We calibrate, rent and repair test equipment.
This Operating and Service Manual applies to the Keysight Technologies C, D, E and F VHF Attenuators. This manual contains information on how to properly use and maintain the integrity of the VHF Attenuators. Topics covered in this document are general information, installation, operating instructions, and replacement parts. The Keysight C dc to MHz manual step attenuator provides precision step attenuation in 1 dB steps from 0 to 12 dB. Attenuator sections are inserted and removed by cam-actuated microswitches which keep lead lengths short. This design minimizes stray capacitances and inductances, and keeps phase shift to a minimum. For HP products a product number. - Examples: LGUA; For Samsung Print products, enter the M/C or Model Code found on the product label. - Examples: “SL-MW/XAA” Include keywords along with product name. Examples: "LaserJet Pro P paper jam", "EliteBook G3 bios update" Need help finding your product name or product number?.
0コメント